Tempered glass is a remarkable material: strong, safe and widely used in facades, balustrades and doors. It also carries a small, well-known risk. Nickel sulphide inclusions can cause a tempered panel to break spontaneously, sometimes years after installation.

Where the risk comes from

Nickel sulphide particles may be present in float glass. During tempering, the glass is heated and rapidly cooled, locking the pane into a stressed state. Over time, a nickel sulphide inclusion can change volume and create enough local stress to trigger breakage.

The probability is low, but the consequences can be serious in overhead, high-level or public applications. That is why project specifications increasingly call for heat soak treatment.

How heat soak treatment works

Heat soak treatment exposes tempered glass to elevated temperature for a controlled period. The process accelerates the transformation of nickel sulphide inclusions, so that panels containing critical inclusions break during the test rather than in service.

  • Panels are processed before delivery, not after installation.
  • The treatment is recorded and traceable by batch.
  • Impact and fragment tests provide additional confidence in the tempering process.

When to specify it

Heat soak treatment is particularly relevant for balustrades, canopies, roof glazing, high-level facade panels and projects where replacement access is difficult. It adds cost and lead time, so the decision should be made early with the glass supplier.

At Casada Glass, heat soak treatment and impact testing are available for tempered glass projects. We recommend discussing the application with our team so that the specification matches the real risk and the project programme.

Share this article

Need glass for a project?

Send your drawings and requirements for a practical, project-specific proposal.

Request a Quote